III Technical Parameters and Equipment List

Technical Parameters

Prototype Product Model \ parameters Range of ozone production (kgO3/h) Required oxygen amount (Nm3/h) Power Regulating range (KW) Input voltage (V) Cooling water consumption (m3/h) Unity machine dimensions (mm)
0.1kg-2kg OZRB-MIOG-0.1kg 0-0.1 1 0-1 220 ≥0.2 400*520*500
OZRB-MIOG-1kg 0-1 10 0-8 380 ≥2 800*800*1900
OZRB-MIOG-2kg 0-2 20 0-16 380 ≥4 1100*1000*2300
>2kg OZRB-MIOG-10kg 0-10 80 0-80 380 ≥20 3600*900*2300
OZRB-MIOG-35kg 0-35 280 0-280 380 ≥70 10000*900*2300
OZRB-MIOG-Nkg 0-N 8N 0-8N 380 ≥2N -

Integrated type / Cabinet type ozone generator

Advantages: Trunk piston style compressor; Each module is used as backup; Wide range of output regulation.

100g (400 x 520 x 500) 35kg (10,000 x 900 x 2,300) 2kg (1,100 x 1,000 x 2,300) ~10kg (3,600 x 900 x 2,300)

Container type ozone generator

Advantages: Convenient and swift; No need equipment room; Shorten the installation and debugging cycle; Position can be adjustable.

100g (400 x 520 x 500) 2kg (1,100 x 1,000 x 2,300)

Technical Parameters of Ozone Generator

S/N Item Unit Parameters
1 Ozone yield adjustment range % 0-100
2 Range of conventional ozone operating concentration g/Nm3 30-150
3 Maximum concentration of the ozone generator g/Nm3 300
4 Ozone emission concentration(theoretical value) in engineering applications ppb <50
5 Operating pressure MPa 0.1-0.13
6 Gas pressure at outlet MPa 0.08-0.128
7 Dew point temperature of air source ≤-60
8 Power consumption for generation of per kilogram of ozone KWh/kg. O3 ≤7.0
9 Volume of cooling water for per kilogram of ozone m3/h 2
10 Temperature of external circulation cooling water at inlet <30
11 Pressure of external circulation cooling water MPa 0.15-0.2
12 Pressure of internal circulation cooling water MPa 0.1-0.15
13 Discharge gap mm ≤0.2
14 Power factor of main power supply of the ozone generator ≥0.99
15 Input power 380V, 50Hz
16 Operating frequency KHz 8-10
17 Output voltage KV 2.5-3.5

Note: power consumption of ozone depends on different ozone concentrations and external ambient conditions (cooling water temperature and water source temperature)